Your phone's compass, the wheel-speed sensor in a car's ABS, the parking sensor in its bumper and the clamp-on flow meter on a water pipe all rely on two solid state effects: the Hall effect and the piezoelectric effect. This module of Physics of Measurements and Sensors (BSC2023, FE Semester 2) explains the Hall effect and how the Hall voltage is measured and used, then the piezoelectric effect and how a piezoelectric crystal is used as a source and detector of ultrasound, and finally two ultrasonic applications: flow measurement and the ultrasonic distance meter. It maps to CO4 (examine the use of appropriate sensors for an application). Numericals on Hall voltage and echo distance are quick scoring questions.
Summary
Hall effect: When a current-carrying conductor or semiconductor is placed in a magnetic field perpendicular to the current, a voltage develops across the specimen in the direction perpendicular to both the current and the field. This is the Hall effect, discovered by E. H. Hall in 1879, and the voltage is the Hall voltage \(V_H\). Explanation: let current I flow along the x-axis in a slab of width w (y-direction) and thickness t (z-direction), with magnetic field B along z. The moving charge carriers (drift velocity \(v_d\)) experience the Lorentz force \(F = qv_dB\) along y, so they pile up on one face, leaving the opposite face with the opposite charge. This builds up a transverse electric field \(E_H\). Equilibrium is reached when the electric force balances the magnetic force: \(qE_H = qv_dB\), so \(E_H = v_dB\). Using \(I = nqv_dA = nqv_dwt\), \(v_d = I/(nqwt)\), and \(V_H = E_Hw = BI/(nqt)\). The Hall coefficient is defined as \(R_H = E_H/(JB) = 1/(nq)\), so \(V_H = R_HBI/t\).
What the Hall effect tells us: (1) The sign of \(V_H\) (or \(R_H\)) shows the type of majority carrier: negative for electrons (n-type), positive for holes (p-type). (2) The carrier concentration \(n = 1/(|R_H|e)\). (3) Combined with conductivity, the Hall mobility \(\mu_H = \sigma|R_H|\). (4) Since \(V_H \propto B\) for a fixed current, a calibrated Hall element measures magnetic field. \(V_H\) is inversely proportional to n, so the effect is very small in metals (n about \(10^{28}\) to \(10^{29}\) per m³) and much larger in semiconductors; Hall sensors therefore use semiconductors such as InSb, InAs, GaAs and Si, made thin (small t) to increase \(V_H\).
Measurement of Hall voltage: A thin rectangular sample is fitted with two current contacts at its ends and two Hall probes on opposite side faces, exactly opposite each other. A constant current source drives a known I (measured by a milliammeter); the sample is placed between the pole pieces of an electromagnet with B (measured by a gaussmeter) perpendicular to its flat face. A high-impedance millivoltmeter (or digital voltmeter) connected to the Hall probes reads \(V_H\). Because the probes are never perfectly opposite, a small IR drop (misalignment voltage) appears even without B; thermoelectric voltages may also be present. These are removed by taking readings for the four combinations of current direction and field direction and averaging them with signs chosen so that the Hall part (which reverses with B) adds up while the offset (which does not reverse with B) cancels. Readings of \(V_H\) against I at constant B, and against B at constant I, should be straight lines; their slopes give \(R_H\). Then n and μ follow.
Hall effect sensors and applications: Hall elements with built-in amplifiers and comparators are made as integrated circuits. Linear Hall sensors give voltage proportional to B (gaussmeters, current sensors that measure the field around a conductor without breaking the circuit, position sensors). Switch type (digital) Hall sensors switch when B crosses a threshold (proximity and limit switches, brushless DC motor commutation, speed sensors with a toothed wheel or magnet, keyboard and lid sensors). They have no moving parts, work in dust and oil and have long life.
Piezoelectric effect: Certain crystals without a centre of symmetry, such as quartz, Rochelle salt and tourmaline, and poled ceramics such as barium titanate and lead zirconate titanate (PZT), develop electric charges on opposite faces when they are mechanically stressed. This is the direct piezoelectric effect, discovered by Jacques and Pierre Curie in 1880. The charge is proportional to the force, \(Q = dF\), where d is the piezoelectric charge coefficient (for quartz about 2.3 pC/N). The voltage across the crystal of capacitance C is \(V = Q/C\). Conversely, when an electric field is applied across the crystal, it changes its dimensions: this is the converse (inverse) piezoelectric effect. An alternating voltage makes the crystal vibrate at the same frequency, and when this frequency equals the natural frequency of the crystal, it vibrates with large amplitude (resonance).
Piezoelectric crystal as an ultrasonic source: Ultrasound is sound of frequency above 20 kHz. In the piezoelectric oscillator, a quartz slab (or PZT disc) is placed between two metal plates that form part of the tank circuit of an electronic oscillator. The plates apply an alternating voltage across the crystal. The tank circuit's capacitor is tuned until its frequency equals the natural frequency of the crystal; the crystal then resonates and emits intense ultrasonic waves. For thickness-mode vibration the fundamental frequency is \(f = \dfrac{1}{2t}\sqrt{\dfrac{E}{\rho}}\), where t is the thickness, E Young's modulus and ρ density of the crystal. Thinner crystals give higher frequencies, so frequencies of a few hundred kHz to several MHz (and above, using overtones) are obtained. The same crystal works as a receiver: an incoming ultrasonic wave stresses it and produces a voltage by the direct effect. Advantages over the magnetostriction method: much higher frequencies, narrow stable output; disadvantage: crystals are costlier. Ultrasonic transducers in practice are PZT discs with a backing (damping) block and a matching layer.
Ultrasonic flow measurement: Two methods are used. (1) Transit-time (time-of-flight) flow meter: two transducers A and B are mounted on opposite sides of a pipe, separated by a path length L inclined at angle θ to the pipe axis. A pulse travelling downstream (with the flow) takes \(t_d = L/(c + v\cos\theta)\) and one travelling upstream takes \(t_u = L/(c - v\cos\theta)\), where c is the speed of sound in the liquid and v the mean flow velocity. The difference \(\Delta t = t_u - t_d \approx 2Lv\cos\theta/c^2\), and exactly \(v = \dfrac{L}{2\cos\theta}\left(\dfrac{1}{t_d} - \dfrac{1}{t_u}\right) = \dfrac{L(t_u - t_d)}{2\cos\theta\,t_ut_d}\). The exact form does not need c, so temperature changes in c are cancelled. Flow rate \(Q = vA\). Used for clean liquids, including clamp-on meters that need no pipe cutting. (2) Doppler flow meter: a continuous ultrasonic beam of frequency f is sent into the liquid at angle θ; particles or bubbles moving with the flow reflect it with a shifted frequency. The frequency shift \(\Delta f = 2fv\cos\theta/c\), so \(v = c\,\Delta f/(2f\cos\theta)\). It needs suspended particles or bubbles, so it is used for slurries, sewage and also for blood flow in medicine. Ultrasonic flow meters have no moving parts or obstruction, no pressure loss, and work with corrosive liquids.
Ultrasonic distance meter: A piezoelectric transducer emits a short burst of ultrasound (typically 40 kHz in air) towards an object. The burst reflects from the object and returns to the receiver (or the same transducer). An electronic timer measures the round-trip echo time t. Since the pulse travels to the object and back, the distance \(d = vt/2\), where v is the speed of sound (about 343 m/s in air at 20 °C, about 1480 to 1500 m/s in water). Temperature compensation is needed in air because \(v \approx 331 + 0.6T\) m/s, T in °C. Applications: parking sensors, level measurement in tanks, robot obstacle avoidance, echo sounding (SONAR) for sea depth, thickness gauging and flaw detection in metals (pulse-echo NDT). Limitations: soft or angled surfaces reflect poorly, there is a minimum distance (dead zone) because the transducer must stop ringing before receiving, and the beam spreads.
Mind map
Solid State Sensors
- Hall effect
- I along x, B along z, VH along y
- VH = BI/(nqt)
- RH = 1/(nq), sign gives carrier type
- μ = σRH
- Measuring VH
- Constant current, electromagnet
- High impedance voltmeter
- Reverse B and I, average
- Hall sensors
- Gaussmeter, current sensor
- Proximity, speed, BLDC motor
- Piezoelectric effect
- Direct: stress gives charge, Q = dF
- Converse: field gives strain
- Quartz, PZT
- Ultrasonic source
- Piezo oscillator at resonance
- f = (1/2t)√(E/ρ)
- Applications
- Transit-time flow meter
- Doppler flow meter
- Distance meter d = vt/2
Deriving the Hall voltage
- A slab of width w and thickness t carries current I along x; a magnetic field B acts along z. Carriers have charge q, concentration n and drift velocity \(v_d\).
- Magnetic Lorentz force on each carrier: \(F_B = qv_dB\), along the y-direction.
- Carriers accumulate on one side face; an equal and opposite charge is left on the other face, creating a transverse Hall field \(E_H\) and force \(F_E = qE_H\) opposing further deflection.
- Equilibrium: \(qE_H = qv_dB\), so \(E_H = v_dB\).
- Current \(I = nqv_dA\) with \(A = wt\), so \(v_d = I/(nqwt)\) and current density \(J = I/(wt)\).
- Hall voltage \(V_H = E_Hw = \dfrac{I}{nqwt}Bw = \dfrac{BI}{nqt}\).
- Hall coefficient \(R_H = \dfrac{E_H}{JB} = \dfrac{1}{nq}\), so \(V_H = \dfrac{R_HBI}{t}\) and \(R_H = \dfrac{V_Ht}{BI}\).
- With conductivity σ known, mobility \(\mu = \sigma|R_H|\).
Transit-time versus Doppler flow meters
| Point | Transit-time | Doppler |
|---|---|---|
| Principle | Difference of upstream and downstream travel times | Frequency shift of waves reflected from moving particles |
| Fluid needed | Clean, homogeneous liquid or gas | Liquid with suspended particles or bubbles |
| Key relation | \(v = L(t_u - t_d)/(2\cos\theta\,t_ut_d)\) | \(v = c\,\Delta f/(2f\cos\theta)\) |
| Accuracy | Higher (about 0.5 to 2 percent) | Lower (a few percent) |
| Uses | Water supply, oil, custody transfer | Slurries, sewage, blood flow |
Important definitions
| Term | Meaning |
|---|---|
| Hall effect | Development of a transverse voltage across a current-carrying specimen placed in a perpendicular magnetic field. |
| Hall voltage | The transverse potential difference \(V_H\) produced by the Hall effect. |
| Hall coefficient | \(R_H = E_H/(JB) = 1/(nq)\); unit m³/C. |
| Hall mobility | \(\mu_H = \sigma|R_H|\), mobility found from Hall and conductivity measurements. |
| Direct piezoelectric effect | Generation of electric charge on certain crystals when mechanically stressed. |
| Converse piezoelectric effect | Mechanical deformation of a piezoelectric crystal when an electric field is applied. |
| Ultrasound | Sound waves of frequency above 20 kHz, beyond human hearing. |
| Resonance (crystal) | Large-amplitude vibration when the applied frequency equals the crystal's natural frequency. |
| Doppler shift | Change of observed frequency due to relative motion between source, reflector and receiver. |
| Pulse-echo method | Measuring distance from the round-trip time of a reflected ultrasonic pulse. |
Formulas
| Formula | Meaning |
|---|---|
| \( V_H = \dfrac{BI}{nqt} = \dfrac{R_HBI}{t} \) | Hall voltage; t is thickness along B. |
| \( R_H = \dfrac{1}{nq} = \dfrac{V_Ht}{BI} \) | Hall coefficient. |
| \( n = \dfrac{1}{|R_H|e},\quad \mu = \sigma|R_H| \) | Carrier concentration and mobility. |
| \( Q = dF,\quad V = \dfrac{Q}{C} \) | Charge and voltage of a piezoelectric element. |
| \( f = \dfrac{1}{2t}\sqrt{\dfrac{E}{\rho}} \) | Fundamental thickness-mode frequency of a crystal. |
| \( d = \dfrac{vt}{2} \) | Pulse-echo distance. |
| \( \Delta t \approx \dfrac{2Lv\cos\theta}{c^2} \) | Transit-time difference. |
| \( v = \dfrac{L(t_u - t_d)}{2\cos\theta\,t_ut_d} \) | Flow velocity from transit times. |
| \( \Delta f = \dfrac{2fv\cos\theta}{c} \) | Doppler frequency shift. |
| \( Q = vA \) | Volume flow rate. |
Key points to remember
- B, I and \(V_H\) are mutually perpendicular.
- \(V_H\) is large in semiconductors (small n) and tiny in metals; thinner samples give larger \(V_H\).
- Negative \(R_H\): electrons are majority carriers; positive: holes.
- Remove misalignment and thermal voltages by reversing B and I.
- Piezoelectricity needs crystals without a centre of symmetry; quartz and PZT are typical.
- Converse effect generates ultrasound; direct effect detects it.
- Resonance frequency is inversely proportional to crystal thickness.
- Pulse-echo distance uses half the round-trip time.
- Transit-time needs clean fluid; Doppler needs particles or bubbles.
- Speed of sound: about 343 m/s in air at 20 °C, about 1480 m/s in water.
Solved examples
Example 1. A semiconductor strip 1 mm thick carries 10 mA in a field of 0.5 T. The carrier concentration is \(10^{21}\) m^-3. Find the Hall voltage and Hall coefficient.
\(V_H = BI/(net) = 0.5\times10\times10^{-3}/(10^{21}\times1.6\times10^{-19}\times10^{-3}) = 5\times10^{-3}/0.16 = 0.03125\) V = 31.25 mV. \(R_H = 1/(ne) = 1/160 = 6.25\times10^{-3}\) m³/C.
Example 2. A sample 0.5 mm thick gives a Hall voltage of 37 μV for 20 mA in 0.5 T. Find \(R_H\) and the carrier concentration.
\(R_H = V_Ht/(BI) = 37\times10^{-6}\times0.5\times10^{-3}/(0.5\times20\times10^{-3}) = 1.85\times10^{-8}/10^{-2} = 1.85\times10^{-6}\) m³/C. \(n = 1/(R_He) = 1/(1.85\times10^{-6}\times1.6\times10^{-19}) = 3.38\times10^{24}\) m^-3.
Example 3. A parking sensor receives the echo 17.5 ms after the pulse. Find the distance of the obstacle (v = 343 m/s).
\(d = vt/2 = 343\times0.0175/2 = 3.00\) m.
Example 4. An echo sounder receives a pulse reflected from the sea bed after 0.04 s. Speed of sound in sea water is 1480 m/s. Find the depth.
\(d = 1480\times0.04/2 = 29.6\) m.
Example 5. A quartz plate 1.5 mm thick has E = \(7.9\times10^{10}\) Pa and ρ = 2650 kg/m³. Find the fundamental frequency of the ultrasonic waves it produces.
\(\sqrt{E/\rho} = \sqrt{7.9\times10^{10}/2650} = 5460\) m/s. \(f = 5460/(2\times1.5\times10^{-3}) = 1.82\times10^{6}\) Hz = 1.82 MHz.
Example 6. In a transit-time meter the path length is 0.2 m at 45° to the axis. The measured times are \(t_d = 135.006\) μs and \(t_u = 135.264\) μs. Find the flow velocity.
\(t_u - t_d = 0.258\) μs. \(v = L(t_u - t_d)/(2\cos\theta\,t_ut_d) = 0.2\times0.258\times10^{-6}/(2\times0.7071\times135.264\times10^{-6}\times135.006\times10^{-6}) \approx 2.0\) m/s. Check with the approximate formula: \(\Delta t = 2Lv\cos\theta/c^2 = 2\times0.2\times2\times0.7071/1480^2 = 2.58\times10^{-7}\) s, as measured.
Example 7. A 2 MHz Doppler flow meter at 60° to the flow measures a shift of 2027 Hz in water (c = 1480 m/s). Find the flow velocity.
\(v = c\Delta f/(2f\cos\theta) = 1480\times2027/(2\times2\times10^6\times0.5) = 1.50\) m/s.
Example 8. A quartz element with d = 2.3 pC/N and capacitance 1 nF is subjected to a force of 50 N. Find the charge and voltage.
\(Q = dF = 2.3\times10^{-12}\times50 = 1.15\times10^{-10}\) C. \(V = Q/C = 1.15\times10^{-10}/10^{-9} = 0.115\) V.
Important questions and answers
Q1. What is the Hall effect? Derive an expression for the Hall voltage and Hall coefficient. (6 marks)
Statement and diagram: slab with I along x, B along z, charges collecting on the faces normal to y, \(V_H\) measured across y. Derivation as in the flow above: magnetic force \(qv_dB\) balanced by electric force \(qE_H\); \(v_d = I/(nqwt)\); \(V_H = E_Hw = BI/(nqt)\); \(R_H = 1/(nq)\). Conclusions: sign of \(R_H\) gives carrier type, magnitude gives n, and \(\mu = \sigma R_H\).
Q2. Explain how Hall voltage is measured experimentally and how it is used. (5 marks)
Set-up: thin rectangular semiconductor sample with current leads and Hall probes, constant current source with milliammeter, electromagnet with gaussmeter, high impedance millivoltmeter across the Hall probes. Procedure: set B, pass known I, read \(V_H\); repeat for several currents and fields. Reverse current and field and average to remove offset (misalignment) and thermoelectric voltages. Plot \(V_H\) against I; slope \(= R_HB/t\) gives \(R_H\). Uses: identify n or p type, find carrier concentration and mobility, measure magnetic field (gaussmeter), measure current without contact, sense position, proximity and speed.
Q3. Explain the piezoelectric effect and the production of ultrasonic waves by a piezoelectric oscillator. (6 marks)
Direct effect: stress on certain non-centrosymmetric crystals (quartz, PZT) shifts positive and negative ions unequally and produces surface charges proportional to the stress. Converse effect: an applied field produces strain. Oscillator: a quartz plate between two metal electrodes is connected to the tank circuit (L, variable C) of a transistor oscillator, often through a coupling coil. The alternating voltage makes the crystal vibrate by the converse effect. When the variable capacitor is tuned so that the oscillator frequency \(1/(2\pi\sqrt{LC})\) equals the natural frequency of the crystal, \(f = (1/2t)\sqrt{E/\rho}\), resonance occurs and the crystal emits strong ultrasonic waves. Advantages: very high frequencies (up to hundreds of MHz with thin crystals or overtones), stable and sharp frequency, efficient. The same crystal detects echoes by the direct effect.
Q4. Explain the working of an ultrasonic flow meter. (5 marks)
Transit-time type: two piezoelectric transducers on opposite walls of the pipe send pulses alternately upstream and downstream along a path L at angle θ to the flow. The downstream pulse is speeded up by the flow component \(v\cos\theta\) and the upstream one slowed: \(t_d = L/(c + v\cos\theta)\), \(t_u = L/(c - v\cos\theta)\). Hence \(v = L(t_u - t_d)/(2\cos\theta\,t_ut_d)\), independent of c. Flow rate Q = vA. Doppler type: an ultrasonic beam is reflected by particles moving with the fluid; the shift \(\Delta f = 2fv\cos\theta/c\) gives v. Advantages: non-intrusive, no pressure drop, no moving parts, bidirectional, clamp-on possible. Limitations: transit-time needs clean fluid, Doppler needs particles; accuracy depends on flow profile and pipe data.
Q5. Explain the ultrasonic distance meter with a block diagram. (5 marks)
Blocks: pulse generator and driver feeding a piezoelectric transmitter; receiver transducer, amplifier and threshold detector; timer (counter) started by the transmitted pulse and stopped by the echo; microcontroller that computes and displays the distance, often with a temperature sensor for correction. Working: a short burst (for example 40 kHz, about 8 cycles) is sent; it reflects from the target; echo time t is measured; \(d = vt/2\). Range typically a few cm to several metres in air. Applications: parking aids, liquid level, robotics, depth sounding, thickness and flaw testing. Errors arise from changes in temperature (speed of sound), absorbent or inclined targets and multiple echoes.
Q6. Why is the Hall voltage larger in semiconductors than in metals? (3 marks)
\(V_H = BI/(nqt)\) is inversely proportional to carrier concentration. For the same current, fewer carriers must drift faster, so the magnetic force per carrier and the resulting Hall field are larger. Semiconductors have n of about \(10^{20}\) to \(10^{24}\) m^-3 versus about \(10^{28}\) to \(10^{29}\) m^-3 in metals, so \(V_H\) is many orders of magnitude larger.
Exam tips
- Draw the Hall slab with x, y, z axes and mark I, B, the force direction and \(V_H\).
- Thickness t in the Hall formula is the dimension along B, not the width.
- Never forget the factor 2 in the echo formula (round trip) and in the Doppler shift (reflection).
- For the piezo oscillator, draw the tank circuit with crystal plates and state the resonance condition.
- Compare transit-time and Doppler meters in a table for 4 to 5 marks.
FAQs
Why is the Hall voltage opposite in sign for n-type and p-type samples?
Electrons and holes moving in opposite directions to carry the same current are pushed to the same face by the magnetic force, but they carry opposite charges, so that face becomes negative for n-type and positive for p-type.
Why do bats and parking sensors use ultrasound rather than audible sound?
Higher frequency means shorter wavelength, so the beam is narrower and reflects from smaller objects, giving better resolution. It is also inaudible to people.
Is quartz still used when PZT is stronger?
Yes. Quartz is extremely stable and is used in clocks and precision force sensors; PZT gives much larger output and is used in most ultrasonic transducers.
Can an ultrasonic distance meter work in vacuum?
No. Sound needs a medium. For vacuum or very long distances, laser (optical) range finders are used.