Back to the page

In the print window, choose “Save as PDF”.

doubtly doubtly.in

MEMS Notes FE Sem 2 Physics for Emerging Fields | MU

Physics for Emerging Fields · Updated 27 Oct 2026 · Read online: www.doubtly.in/mu-fe-physics-emerging-fields-mems-notes/

Your phone knows when you turn it sideways, a car fires its airbag in a few milliseconds after a crash, and a smartwatch counts your steps. All of these use Micro Electro-Mechanical Systems (MEMS): tiny machines, with parts a few micrometres in size, built on silicon chips together with electronics. This module of Physics for Emerging Fields gives an overview of MEMS, their intrinsic characteristics, microsensors and microactuators, the main materials used to make them (silicon, polymers and metals), and how MEMS devices are packaged and encapsulated. It maps to course outcome CO3 (illustrate the use of MEMS sensors) and supports the lab experiments on a MEMS pressure sensor and a MEMS microphone.

Summary

Overview of MEMS: MEMS are miniature devices or systems that combine mechanical elements (beams, diaphragms, gears, mirrors, channels), sensors, actuators and electronics on a common substrate, usually silicon, made by microfabrication. Their critical dimensions range from about 1 μm to 1 mm. The electronics (the "brain") process signals, the sensors (the "eyes and ears") gather information from the environment by measuring mechanical, thermal, chemical, optical or magnetic quantities, and the actuators (the "arms") respond by moving, pumping, filtering or switching. MEMS grew out of the integrated circuit industry and use the same tools: photolithography, thin film deposition and etching. Important milestones include the discovery of the large piezoresistive effect in silicon (1954), silicon pressure sensors in the 1960s and 70s, surface micromachined accelerometers for airbags in the early 1990s, and the Texas Instruments Digital Micromirror Device (DMD) for projectors. Today MEMS are found in phones (accelerometers, gyroscopes, microphones, RF filters), cars (airbag accelerometers, tyre pressure sensors, stability control gyros), printers (inkjet nozzles), medicine (blood pressure sensors, lab-on-chip) and industry. When the dimensions go below 100 nm the field is called NEMS (nano electro-mechanical systems).

Intrinsic characteristics of MEMS: Three features make MEMS special. (i) Miniaturisation: devices are very small and light, so they respond fast (high resonant frequency), consume little power and can be placed where large sensors cannot go. Scaling down changes which forces matter: volume (and mass, inertia, weight) falls as \(L^3\) while surface area falls as \(L^2\), so the surface-to-volume ratio rises as \(1/L\). Surface forces such as friction, adhesion, surface tension and electrostatic force become dominant, while gravity and inertia become unimportant. (ii) Microelectronics integration: mechanical parts and signal-processing circuits can be made on the same chip or in the same package, giving smart sensors with amplification, calibration and digital output, less wiring and less noise. (iii) Parallel (batch) fabrication with precision: thousands of identical devices are made at once on a wafer by lithography, with dimensional accuracy of about a micrometre, so cost per device is very low and devices are uniform. Other characteristics are low power, high sensitivity and reliability, and mass production. Limitations include stiction (parts sticking together), sensitivity to the environment and complex packaging.

Microsensors: A microsensor converts a physical or chemical quantity into an electrical signal. Common sensing principles are piezoresistive (resistance changes with strain), capacitive (capacitance changes with gap or area), piezoelectric (charge generated by stress), thermal and resonant (frequency changes). Examples: (i) Pressure sensor: a thin silicon diaphragm, formed by etching a cavity from the back of the wafer, bends under pressure; four piezoresistors diffused at the edges of the diaphragm form a Wheatstone bridge whose output voltage is proportional to pressure. Used in cars (manifold pressure, tyre pressure), medical blood pressure monitors and weather stations. (ii) Accelerometer: a proof mass hangs on folded spring beams; under acceleration a the mass moves by \(x = ma/k\); interdigitated comb fingers on the mass and the frame form capacitors whose values change with x, and the circuit converts this into voltage. Used for airbag deployment, screen rotation, step counting and vibration monitoring. (iii) Gyroscope: a mass is driven to vibrate; when the device rotates, the Coriolis force deflects the mass in a perpendicular direction, and this deflection, sensed capacitively, is proportional to the angular velocity. Used in phones, drones and vehicle stability systems. (iv) MEMS microphone: a flexible diaphragm and a perforated rigid back plate form a capacitor; sound pressure moves the diaphragm and changes the capacitance. Others include flow sensors, gas and humidity sensors, temperature sensors and biosensors.

Microactuators: A microactuator converts an electrical signal into motion or force. Main types: (i) Electrostatic: attraction between oppositely charged plates; parallel-plate actuators give a force \(F = \varepsilon_0AV^2/2d^2\), and comb-drive actuators with many interleaved fingers give lateral motion with a force independent of position; used in micromirrors, resonators and RF switches. (ii) Thermal: a beam or bimorph of two materials with different expansion coefficients bends when heated by a current; large force and displacement but slow and power-hungry. (iii) Piezoelectric: a thin film of PZT or AlN expands or contracts with applied voltage; fast and precise; used in inkjet heads, ultrasonic transducers and micro-positioners. (iv) Magnetic: a current-carrying coil or magnetic film in a magnetic field experiences a force; used in micro-relays and scanners. (v) Shape memory alloy (for example NiTi), which recovers a programmed shape when heated. Examples of devices: the DMD, an array of hundreds of thousands to millions of tiny aluminium mirrors each tilted by electrostatic force to switch a pixel on or off; inkjet print heads that eject droplets by a thermal bubble or a piezo element; micropumps and microvalves for drug delivery; micro-grippers and RF MEMS switches.

Materials for MEMS, silicon: Single-crystal silicon is the main MEMS material. It is abundant, cheap and available as high-purity wafers; its processing technology is mature from the IC industry; it has a Young's modulus of about 130 to 190 GPa (similar to steel) with a density of only 2.33 g/cm³ (lighter than aluminium); it is perfectly elastic at room temperature with almost no fatigue or hysteresis, so it is ideal for springs and diaphragms; its melting point is 1414 °C; it shows strong piezoresistivity, useful for sensing; and it can be etched anisotropically (KOH etching stops at {111} planes, giving V-grooves and cavities with 54.74° walls). Silicon compounds are also widely used: silicon dioxide (insulator, sacrificial layer, mask), silicon nitride (hard insulator, mask, membranes), polysilicon (structural layer in surface micromachining) and silicon carbide (harsh, high-temperature environments). Silicon is brittle, however, so it can crack under shock.

Materials for MEMS, polymers: Polymers are cheap, flexible, light and biocompatible, and they can be moulded or cast easily, so they are used especially in microfluidics, biomedical MEMS and flexible sensors. Important ones: SU-8 (an epoxy-based negative photoresist that forms thick, high aspect ratio structures), PDMS (polydimethylsiloxane, a soft, transparent, gas-permeable silicone used for microfluidic channels and lab-on-chip), polyimide (heat resistant, flexible substrates and insulating layers), PMMA (used in LIGA and hot embossing), parylene (a conformal coating deposited from vapour, used for encapsulation and as a biocompatible layer) and liquid crystal polymers. Some conductive and piezoelectric polymers such as PVDF are used for sensing. Disadvantages: low stiffness, low temperature limits and poor hermeticity.

Materials for MEMS, metals: Metals are deposited as thin films by evaporation, sputtering or electroplating. They serve as electrodes, interconnects, mirrors, heaters and sometimes structural parts. Aluminium: good conductor and reflector, used for wiring and the mirrors of DMDs. Gold: excellent conductivity and corrosion resistance, used for contacts, wire bonding and RF switches; needs an adhesion layer of chromium or titanium. Nickel and copper: electroplated to make thick structures (LIGA) and magnetic parts (nickel). Platinum: stable at high temperature, used for temperature sensors and heaters. Tungsten and titanium: heaters, adhesion layers and hard structures. NiTi shape memory alloy: actuators.

Packaging and encapsulation of MEMS: Packaging protects the delicate microstructure from mechanical damage, moisture, dust and chemicals, while still allowing it to interact with the quantity it senses (pressure, fluid, light, sound), and it provides electrical connections and heat removal. Unlike an IC, which can be fully sealed, many MEMS need openings or special atmospheres, so packaging is often the most expensive part of a MEMS product. Packaging is done at three levels: die level (releasing and protecting the individual chip, die preparation and passivation), device level (attaching the die to a substrate or lead frame, wire bonding, adding the signal conditioning chip, sealing) and system level (integrating the packaged device with circuits and other components on a board). Key steps and techniques: die attach (adhesive, solder or eutectic), wire bonding or flip-chip bonding for electrical connection, and wafer-level bonding to cap the device: anodic bonding (silicon to sodium-containing glass at a few hundred °C with a high voltage), fusion (direct) bonding of silicon to silicon at high temperature, eutectic bonding (for example gold-silicon at 363 °C) and adhesive bonding with polymers. Encapsulation means sealing the device in a protective material or cavity: hermetic sealing in metal or ceramic cases, vacuum sealing for resonators and gyroscopes (to reduce air damping), plastic moulding with a gel or cap over the moving part, and conformal coatings of parylene. Packaging must also avoid stress on the die (which shifts sensor output), prevent stiction and allow testing and calibration.

Mind map

Micro Electro-Mechanical Systems

  • Overview
    • Mechanical parts + sensors + actuators + electronics
    • 1 μm to 1 mm
    • Phones, cars, printers, medicine
  • Intrinsic characteristics
    • Miniaturisation, S/V ∝ 1/L
    • Microelectronics integration
    • Parallel fabrication with precision
  • Microsensors
    • Piezoresistive pressure sensor
    • Capacitive accelerometer
    • Coriolis gyroscope
    • MEMS microphone
  • Microactuators
    • Electrostatic: plate, comb drive
    • Thermal bimorph
    • Piezoelectric, magnetic, SMA
    • DMD, inkjet, micropump
  • Materials
    • Silicon, SiO2, Si3N4, polysilicon
    • Polymers: SU-8, PDMS, polyimide, parylene
    • Metals: Al, Au, Ni, Cu, Pt
  • Packaging
    • Die, device, system levels
    • Die attach, wire bonding
    • Anodic, fusion, eutectic bonding
    • Hermetic, vacuum, plastic encapsulation

Working of a capacitive MEMS accelerometer

  1. A proof mass of mass m is suspended from the frame by folded silicon beams that act as a spring of stiffness k.
  2. Fingers attached to the mass sit between fixed fingers on the frame, forming two capacitors C1 and C2 (a differential pair).
  3. At rest the mass is centred, so C1 = C2 and the output is zero.
  4. When the chip accelerates, the inertia of the mass makes it lag behind the frame; the spring force balances it at displacement \(x = ma/k\).
  5. The gap on one side decreases and on the other side increases, so C1 rises and C2 falls (C = εA/d).
  6. An on-chip circuit applies AC signals to the fixed fingers and measures the imbalance, giving a voltage proportional to x and hence to a.
  7. The mechanical resonant frequency \(f_0 = \frac{1}{2\pi}\sqrt{k/m}\) sets the bandwidth; air damping in the package controls ringing.
  8. Three such structures at right angles give a 3-axis accelerometer used for airbags, screen rotation and step counting.

Important definitions

TermMeaning
MEMSMicro electro-mechanical systems: miniature integrated devices combining mechanical and electrical components, with feature sizes from about 1 μm to 1 mm, made by microfabrication.
MicrosensorA micro-scale device that converts a physical, chemical or biological quantity into an electrical signal.
MicroactuatorA micro-scale device that converts an electrical signal into mechanical motion or force.
TransducerA device that converts energy from one form to another; sensors and actuators are both transducers.
Proof massThe suspended mass in an inertial sensor whose displacement measures acceleration.
PiezoresistivityChange in electrical resistivity of a material when it is strained.
Comb driveAn electrostatic actuator with interleaved comb fingers that produces lateral motion.
Bulk micromachiningForming structures by etching deep into the silicon substrate itself.
Surface micromachiningForming structures from thin films deposited on the substrate, freed by etching a sacrificial layer.
StictionPermanent sticking of microstructures to each other or to the substrate due to surface forces.
PackagingEnclosing a MEMS die to protect it, connect it electrically and let it interface with its environment.
EncapsulationSealing the device in a protective material, cap or cavity (hermetic, vacuum or plastic).
Anodic bondingJoining silicon to sodium-containing glass using heat and a high voltage.
Hermetic sealA seal that is airtight and does not let moisture or gases pass.

Formulas

FormulaMeaning
\( \dfrac{S}{V} = \dfrac{6L^2}{L^3} = \dfrac{6}{L} \)Surface-to-volume ratio of a cube of side L; rises as size falls.
\( C = \dfrac{\varepsilon_0\varepsilon_rA}{d} \)Parallel-plate capacitance used in capacitive sensors.
\( F = \dfrac{\varepsilon_0AV^2}{2d^2} \)Electrostatic force between parallel plates at voltage V (in air).
\( x = \dfrac{ma}{k} \)Static displacement of a proof mass under acceleration a.
\( f_0 = \dfrac{1}{2\pi}\sqrt{\dfrac{k}{m}} \)Resonant frequency of a spring-mass microstructure.
\( \dfrac{\Delta R}{R} = \pi_l\sigma_l + \pi_t\sigma_t \)Piezoresistive change; π piezoresistive coefficients, σ longitudinal and transverse stresses.
\( V_{out} = \dfrac{\Delta R}{R}V_s \)Output of a full Wheatstone bridge with two resistors increasing and two decreasing by ΔR.
\( F_c = 2m\,\Omega v \)Coriolis force on a mass moving with velocity v in a frame rotating at Ω (for v perpendicular to the rotation axis).

Key points to remember

Solved examples

Example 1. A cube-shaped structure is scaled down from 1 mm to 10 μm side. Find its surface-to-volume ratio before and after. What does this imply?

\(S/V = 6/L\). For L = 1 mm: \(6/10^{-3} = 6\times10^{3}\) m^-1. For L = 10 μm: \(6/10^{-5} = 6\times10^{5}\) m^-1, which is 100 times larger. Surface effects (friction, adhesion, surface tension, electrostatic force) therefore become far more important than weight and inertia in the small device.

Example 2. A capacitive sensor has square plates of side 200 μm separated by an air gap of 2 μm. Find the capacitance.

\(A = (200\times10^{-6})^2 = 4\times10^{-8}\) m². \(C = \varepsilon_0A/d = 8.85\times10^{-12}\times4\times10^{-8}/(2\times10^{-6}) = 1.77\times10^{-13}\) F \(= 0.177\) pF. Such small capacitances are why the read-out circuit must be on the same chip.

Example 3. For the plates of Example 2, find the electrostatic force when 5 V is applied.

\(F = \dfrac{\varepsilon_0AV^2}{2d^2} = \dfrac{8.85\times10^{-12}\times4\times10^{-8}\times25}{2\times(2\times10^{-6})^2} = \dfrac{8.85\times10^{-18}}{8\times10^{-12}} = 1.11\times10^{-6}\) N, about 1.1 μN, enough to move a microstructure.

Example 4. A proof mass of 1 μg (10^-9 kg) is supported by springs of stiffness 1 N/m. Find its resonant frequency and its displacement under an acceleration of 10 g (98.1 m/s²).

\(f_0 = \dfrac{1}{2\pi}\sqrt{\dfrac{1}{10^{-9}}} = \dfrac{31623}{2\pi} = 5.03\times10^{3}\) Hz \(\approx 5\) kHz. Displacement \(x = ma/k = 10^{-9}\times98.1/1 = 9.81\times10^{-8}\) m \(\approx 98\) nm. Such tiny motions are measured as changes in capacitance.

Example 5. A piezoresistive bridge with a 5 V supply gives a fractional resistance change ΔR/R = 0.2 percent at full-scale pressure. Find the full-scale output.

For a full bridge with two arms increasing and two decreasing by ΔR, \(V_{out} = (\Delta R/R)V_s = 0.002\times5 = 0.01\) V \(= 10\) mV. The on-chip amplifier raises this to a usable level.

Important questions and answers

Q1. What are MEMS? Give an overview with applications. (5 marks)

MEMS are miniature systems that integrate mechanical elements, sensors, actuators and electronics on a common silicon substrate using microfabrication; dimensions range from about 1 μm to 1 mm. The electronics process data while the sensors and actuators interact with the environment, so the device can sense, decide and act. They are made by batch processes adapted from IC technology: lithography, deposition, etching, bulk and surface micromachining and LIGA. Applications: automotive (airbag accelerometers, tyre pressure sensors, gyroscopes for stability control, manifold pressure sensors); consumer (accelerometers, gyroscopes, magnetometers and microphones in phones, game controllers, wearables); printers (inkjet heads); displays (DMD projectors); medical (disposable blood pressure sensors, drug delivery micropumps, lab-on-chip, hearing aids); communications (RF MEMS switches, resonators, filters); industry and defence (vibration monitoring, navigation).

Q2. Explain the intrinsic characteristics of MEMS. (5 marks)

(i) Miniaturisation: small size and mass give fast response, high resonant frequency, low power and the ability to fit into small spaces; with scaling, volume ∝ L³ and area ∝ L², so S/V ∝ 1/L, and surface forces dominate over inertia; this favours electrostatic actuation and causes stiction. (ii) Microelectronics integration: the mechanical sensor or actuator is built on the same chip or package as the circuits for amplification, signal conditioning, calibration and communication, giving smart, compact, low-noise systems. (iii) Parallel fabrication with precision: lithography makes thousands of identical devices on one wafer with micrometre precision, lowering cost and giving uniform performance. These lead to low cost, high reliability, low power and mass production.

Q3. Explain the working of a MEMS piezoresistive pressure sensor. (5 marks)

A cavity is etched from the back of a silicon wafer, leaving a thin square diaphragm (a few to tens of micrometres thick). Four piezoresistors are diffused into the top surface near the edges, where stress is greatest: two oriented to feel tensile stress along their length and two oriented to feel it across. They are connected as a Wheatstone bridge. When pressure acts on the diaphragm it bends; the stresses change the resistances, two increasing and two decreasing, and the bridge becomes unbalanced, giving an output voltage proportional to pressure. The reference side of the cavity may be sealed under vacuum (absolute sensor) or open (gauge or differential sensor). Uses: engine manifold pressure, tyre pressure, blood pressure, altimeters.

Q4. Distinguish between microsensors and microactuators with examples. (3 marks)

A microsensor converts a non-electrical input (pressure, acceleration, rotation, sound, temperature, flow, chemicals) into an electrical output; examples: pressure sensor, accelerometer, gyroscope, microphone, gas sensor. A microactuator converts an electrical input into mechanical output (motion, force, flow); examples: comb-drive actuator, DMD micromirror, inkjet nozzle, micropump, microvalve, RF switch. Sensors measure; actuators act. Both often use the same principles in reverse (for example piezoelectric).

Q5. Describe electrostatic and thermal microactuators. (5 marks)

Electrostatic: two electrodes with a voltage V across a gap attract each other. In a parallel-plate actuator, \(F = \varepsilon_0AV^2/2d^2\), which rises sharply as the gap closes and leads to pull-in when the plate moves about one third of the gap. A comb drive uses many interleaved fingers; the force acts sideways and is constant over the travel, \(F = n\varepsilon_0tV^2/g\) for n movable fingers of thickness t, each with a gap g on both sides. Advantages: simple, fast, almost no power at DC, compatible with silicon processing; used in micromirrors, resonators, RF switches. Thermal: a current heats a structure that expands. In a bimorph two layers with different expansion coefficients bend when heated; in a hot-arm/cold-arm actuator one thin arm heats more than a thick arm, so the structure bends. Advantages: large force and displacement at low voltage. Disadvantages: slow (thermal time constant) and higher power consumption.

Q6. Why is silicon the most widely used MEMS material? (5 marks)

Silicon is abundant and available as cheap, extremely pure single-crystal wafers. It has Young's modulus about 130 to 190 GPa, close to steel, but density 2.33 g/cm³, lower than aluminium, giving a high stiffness-to-weight ratio and high resonant frequencies. It is perfectly elastic up to fracture at room temperature, with virtually no hysteresis or fatigue, so springs and diaphragms are stable. Its melting point (1414 °C) is high and its thermal expansion is low, so it is dimensionally stable. It is strongly piezoresistive, giving built-in strain sensing. Its oxide and nitride are excellent insulators and masks, and it can be etched anisotropically in KOH to form precise cavities. Above all, the whole IC fabrication technology can be used, so electronics can be integrated. Its weakness is brittleness.

Q7. Write a note on polymers and metals used in MEMS. (5 marks)

Polymers: low cost, flexible, light and often biocompatible, processed by spin coating, moulding or embossing. SU-8 makes thick high aspect ratio structures and moulds; PDMS is used for microfluidic channels, valves and lab-on-chip; polyimide gives flexible substrates and insulation; PMMA is used in LIGA and embossing; parylene is a vapour-deposited conformal coating for encapsulation; PVDF provides piezoelectric sensing. Limitations: low stiffness, low temperature tolerance, absorption of moisture. Metals: deposited as thin films by evaporation, sputtering or electroplating; Al for interconnects and mirrors, Au for contacts, bond pads and RF switches (with Cr or Ti adhesion layer), Ni and Cu electroplated for thick and magnetic parts, Pt for temperature sensors and heaters, W and Ti for heaters and adhesion layers, NiTi for shape memory actuators.

Q8. Explain packaging and encapsulation of MEMS. (5 marks)

Purpose: mechanical support and protection, protection from moisture, dust and corrosion, electrical connection, heat removal and a controlled interface with the measured medium. Challenges: moving parts must be free, many devices must be open to the environment (pressure, fluid, light), some need vacuum, and package stress can shift the output; packaging can be the largest part of the cost. Levels: die level (release, passivation, die separation), device level (die attach, wire bonding or flip-chip, adding the ASIC, sealing), system level (assembly on a circuit board with other parts). Bonding methods: anodic (silicon to glass with heat and high voltage), fusion (silicon to silicon at high temperature), eutectic (Au-Si), adhesive (polymer). Encapsulation: hermetic sealing in metal or ceramic packages, vacuum sealing for gyroscopes and resonators, wafer-level capping, plastic moulding with protective gel, parylene conformal coating. Testing and calibration follow packaging.

Exam tips

FAQs

How small is a MEMS device compared with a human hair?

A human hair is about 50 to 100 μm thick. Many MEMS beams and comb fingers are only 2 to 5 μm wide, so several of them could sit across one hair.

What is the difference between MEMS and NEMS?

MEMS have features from about 1 μm to 1 mm; NEMS have features below about 100 nm, where quantum and molecular effects begin to matter.

Why do MEMS parts stick together (stiction)?

At micro scale, surface forces such as capillary attraction from moisture and van der Waals forces are much stronger than the restoring spring forces, so parts that touch may not separate. Drying techniques, anti-stiction coatings and hermetic packaging prevent it.

Are MEMS microphones better than ordinary microphones?

They are smaller, more uniform, can withstand reflow soldering and can include digital output, so they are used in almost all phones and earbuds, though large studio microphones still give better sound in some uses.

These notes follow the University of Mumbai first-year engineering syllabus (NEP 2020, Physics for Emerging Fields, Semester II) and were prepared with AI help and checked.

Practise this on Doubtly (free)