Water and Wastewater Notes FE Sem 2 Environmental Chemistry | MU
On this page
Mumbai's Mithi river, the foaming lakes of Bengaluru and the green scum on village ponds are all examples of water pollution that chemistry can measure and engineering can fix. This module of Environmental Chemistry and Non-conventional Energy Sources (BSC2032, FE Semester 2) classifies water pollutants, explains how four key parameters (hardness, pH, dissolved oxygen and chloride) are monitored, distinguishes point and non-point sources, describes the characteristics of wastewater and three lake problems (acidification, eutrophication and thermal stratification), explains primary, secondary (activated sludge) and tertiary treatment, and shows why BOD and COD matter in treatment design. It maps to CO2. The syllabus specifically asks for numericals on hardness, DO, chloride, BOD and COD, so practise them well.
Summary
Classification of water pollutants: (1) Organic pollutants: biodegradable matter from sewage, food and dairy industries and agricultural runoff, which consumes dissolved oxygen as it decays; also oils, detergents, pesticides, phenols and other synthetic organics, some of which are persistent and toxic. (2) Inorganic pollutants: acids and alkalis, salts (chlorides, sulphates), nutrients (nitrates and phosphates from fertilisers and detergents), and toxic heavy metals such as mercury, lead, cadmium, chromium and arsenic, and fluoride. (3) Suspended solids: silt, clay, sand, organic particles and plankton that make water turbid, cut off light, smother aquatic habitats and carry adsorbed pollutants and microbes. (4) Radioactive pollutants: radionuclides such as radium, uranium, strontium-90, iodine-131 and cesium-137 from mining and processing of radioactive ores, nuclear reactors, hospitals and research; they cause cancer and genetic damage. (5) Heat (thermal pollution): hot cooling water from power plants and industries raises the temperature of rivers and lakes, which lowers dissolved oxygen (gas solubility falls with temperature), speeds up metabolism and decay and can kill fish. Pathogens (bacteria, viruses, protozoa) from sewage are also an important biological category.
Hardness: Hardness is the soap-consuming capacity of water, caused mainly by dissolved calcium and magnesium salts. Temporary (carbonate) hardness is due to bicarbonates of Ca and Mg and is removed by boiling (\(Ca(HCO_3)_2 \rightarrow CaCO_3 + H_2O + CO_2\)). Permanent (non-carbonate) hardness is due to chlorides and sulphates of Ca and Mg and is not removed by boiling. Hardness is expressed as mg/L (ppm) of CaCO3 equivalent: \(\text{hardness} = \text{mass of salt}\times\dfrac{100}{\text{molar mass of salt}}\) for salts of divalent ions (equivalently, mass × 50/equivalent weight). Molar masses used: Ca(HCO3)2 162, Mg(HCO3)2 146, CaSO4 136, MgSO4 120, CaCl2 111, MgCl2 95, CaCO3 100. Measurement by the EDTA (complexometric) method: the water sample is buffered to pH 10 with NH4Cl-NH4OH and Eriochrome Black T (EBT) indicator is added; EBT forms a wine red complex with Ca²⁺ and Mg²⁺. EDTA, a stronger complexing agent, is titrated in; it removes the metal ions from the indicator, and at the end point the colour changes from wine red to blue. The EDTA is first standardised against standard hard water (for example 1 mg CaCO3 per mL). Total hardness is found with the raw sample; permanent hardness with a sample that has been boiled, filtered and made up to volume; temporary hardness is the difference.
pH: pH \(= -\log_{10}[H^+]\) measures acidity; 7 is neutral at 25 °C, drinking water should be in the range 6.5 to 8.5 (BIS IS 10500). pH is measured by a pH meter with a glass electrode (whose potential varies by about 59 mV per pH unit at 25 °C) and a reference electrode, after calibration with standard buffer solutions (for example pH 4.0, 7.0 and 9.2), or roughly by indicator papers and universal indicator. Low pH increases corrosion and dissolves metals; high pH causes scaling and reduces chlorine disinfection efficiency.
Dissolved oxygen (DO): DO is the amount of oxygen gas dissolved in water, about 9 mg/L at 20 °C when saturated (about 8.3 mg/L at 25 °C). Fish need at least about 4 to 5 mg/L. It is measured by the Winkler (iodometric) method: the sample is collected without air bubbles in a BOD bottle; manganese sulphate and alkaline potassium iodide (with sodium azide to remove nitrite interference) are added. Manganous hydroxide forms and is oxidised by the dissolved oxygen to a brown precipitate of manganic oxyhydroxide: \(Mn^{2+} + 2OH^- \rightarrow Mn(OH)_2\); \(2Mn(OH)_2 + O_2 \rightarrow 2MnO(OH)_2\). On acidifying with concentrated H2SO4, the Mn(IV) oxidises iodide to iodine: \(MnO(OH)_2 + 4H^+ + 2I^- \rightarrow Mn^{2+} + I_2 + 3H_2O\). The liberated iodine, equivalent to the DO, is titrated with standard sodium thiosulphate using starch (blue to colourless): \(I_2 + 2S_2O_3^{2-} \rightarrow 2I^- + S_4O_6^{2-}\). Since 1 mol O2 gives 2 mol I2 and needs 4 mol thiosulphate, the equivalent weight of O2 is 8, so \(DO\ (mg/L) = \dfrac{N \times V \times 8 \times 1000}{V_{sample}}\). DO meters with membrane electrodes are used in the field.
Chloride: Chloride enters water from sewage, industrial effluents, seawater intrusion and natural salts. High chloride gives a salty taste (BIS acceptable limit 250 mg/L, permissible 1000 mg/L in the absence of an alternative source) and corrodes metals. It is measured by Mohr's (argentometric) method: the neutral or slightly alkaline sample (pH about 7 to 8) is titrated with standard silver nitrate using potassium chromate indicator. Silver chloride precipitates first (white) because it is less soluble: \(Ag^+ + Cl^- \rightarrow AgCl\). After all chloride is precipitated, the next drop forms brick-red silver chromate, marking the end point: \(2Ag^+ + CrO_4^{2-} \rightarrow Ag_2CrO_4\). A blank is run to correct for the indicator. \(Cl^-\ (mg/L) = \dfrac{N \times V \times 35.45 \times 1000}{V_{sample}}\).
Point and non-point sources: Point sources discharge pollutants at a single, identifiable location such as a sewage outfall, an industrial effluent pipe or a power plant's cooling water outlet; they are easier to monitor, treat and regulate (through consent conditions under the Water (Prevention and Control of Pollution) Act, 1974). Non-point sources are diffuse and spread over large areas: agricultural runoff carrying fertilisers and pesticides, urban storm water, runoff from mines and construction sites, and atmospheric deposition. They are hard to trace and are controlled through land management practices such as buffer strips, careful fertiliser use and storm water management.
Characteristics of wastewater: Physical: colour, odour, temperature, turbidity and solids (total solids, total dissolved solids, total suspended solids; settleable solids). Chemical: pH, BOD, COD, total organic carbon, nitrogen (ammonia, nitrate), phosphorus, oil and grease, chlorides, sulphates, heavy metals and toxic organics. Biological: bacteria, viruses, protozoa and helminths; coliforms are used as indicators of faecal pollution. Typical untreated domestic sewage has BOD of about 200 to 300 mg/L and COD of about 400 to 600 mg/L, while treated effluent standards are typically a BOD of 30 mg/L or less, with stricter limits (as low as 10 mg/L) applied to newer sewage treatment plants.
Acidification of lakes: Lakes in areas with thin soils on granite and with little limestone have low buffering (alkalinity). Acid rain and acid mine drainage lower their pH. Below about pH 6 sensitive species disappear and below pH 5 most fish cannot reproduce. Acid also mobilises aluminium and heavy metals from soils and sediments, which are toxic. Remedy: reduce SO2 and NOx emissions; liming (adding powdered limestone) neutralises lakes temporarily.
Eutrophication: Eutrophication is the over-enrichment of a water body with nutrients, especially phosphates and nitrates from sewage, detergents and fertiliser runoff, which causes excessive growth of algae and aquatic plants (algal blooms, water hyacinth). The algae cover the surface and block light; when they die, bacteria decompose them and consume large amounts of dissolved oxygen, so the bottom water becomes anoxic, fish die, and hydrogen sulphide and methane are produced, giving foul smell. Some blue-green algae (cyanobacteria) produce toxins. The lake slowly fills with organic sediment and ages rapidly. Control: treat sewage with nutrient removal, ban or limit phosphate detergents, control fertiliser use, divert inflows, harvest weeds, aerate and dredge.
Thermal stratification of lakes: In summer the sun warms the surface layer of a deep lake. Warm water is less dense, so the lake divides into three layers: the epilimnion (warm, well mixed, oxygen rich upper layer), the metalimnion or thermocline (middle layer where temperature falls rapidly with depth) and the hypolimnion (cold, dense, dark bottom layer). The thermocline prevents mixing, so the hypolimnion does not get fresh oxygen; decomposition of organic matter there can make it anoxic, releasing iron, manganese, phosphate and H2S from sediments. In autumn the surface cools, densities equalise and the lake mixes (overturn), bringing nutrients up and oxygen down; in cold climates a winter stratification and spring overturn also occur (water is densest at 4 °C). Stratification worsens the effects of eutrophication and affects the quality of water drawn from reservoirs.
Wastewater treatment: Preliminary treatment removes large and heavy materials: bar screens remove rags and floating debris; grit chambers settle sand and gravel; skimming removes oil and grease. Primary treatment: primary sedimentation (clarifiers) settles suspended solids for about 2 hours, removing about 50 to 70 percent of suspended solids and 25 to 40 percent of BOD; the settled solids are primary sludge. Coagulation with alum may be used for some industrial wastes. Secondary (biological) treatment: microorganisms oxidise dissolved and colloidal organic matter to CO2, water and new cells, removing about 85 to 95 percent of BOD. In the activated sludge process (ASP), settled sewage enters an aeration tank where it is mixed with a large population of microorganisms (activated sludge, as flocs) and air is blown in by diffusers or surface aerators for about 4 to 8 hours. Microbes consume the organic matter. The mixed liquor flows to a secondary clarifier where the flocs settle; part of the settled sludge (about 25 to 50 percent of the flow) is returned to the aeration tank as return activated sludge to keep the microbial population high (mixed liquor suspended solids typically about 1500 to 3000 mg/L), and the excess is wasted to sludge treatment. The clear effluent goes on to disinfection or tertiary treatment. Other secondary processes are trickling filters, oxidation ponds and upflow anaerobic sludge blanket (UASB) reactors. Sludge is thickened, digested anaerobically (producing biogas), dewatered and disposed of or used as manure. Tertiary (advanced) treatment polishes the effluent for reuse or for discharge into sensitive waters: removal of nitrogen (nitrification-denitrification, ammonia stripping), phosphorus (chemical precipitation with alum, lime or ferric salts, or biological removal), remaining suspended solids (sand filtration), dissolved organics (activated carbon adsorption), dissolved salts (reverse osmosis, ion exchange, electrodialysis) and pathogens (chlorination, UV, ozonation).
BOD and COD: Biochemical oxygen demand (BOD) is the amount of dissolved oxygen needed by aerobic microorganisms to decompose the biodegradable organic matter in one litre of water, usually measured over 5 days at 20 °C (BOD5); in India the 3-day test at 27 °C is also used. Method: the sample is diluted with oxygen-saturated dilution water containing nutrients (and seeded with microbes if needed); initial DO (D1) is measured; the bottle is incubated in the dark for 5 days at 20 °C; final DO (D2) is measured; \(BOD = (D_1 - D_2)/P\), where P is the fraction of sample in the bottle. Chemical oxygen demand (COD) is the amount of oxygen equivalent to the oxidisable organic (and some inorganic) matter, determined by refluxing the sample with excess standard potassium dichromate in 50 percent sulphuric acid for 2 hours, with silver sulphate as catalyst and mercuric sulphate to complex chloride. The unused dichromate is titrated with standard ferrous ammonium sulphate (FAS) using ferroin indicator (blue-green to reddish brown); a blank is run with distilled water. \(COD = \dfrac{(V_b - V_s)\times N\times8\times1000}{V_{sample}}\). Relevance in wastewater treatment: BOD measures the load of biodegradable matter, so it is used to design aeration tanks and oxygen supply, assess treatment efficiency (percent BOD removal) and check discharge standards. COD is quick (3 hours instead of 5 days), measures nearly all organics including non-biodegradable and toxic ones, and is used for routine plant control. COD is always greater than or equal to BOD. The ratio BOD/COD indicates biodegradability: above about 0.5 the waste is readily treatable biologically; below about 0.3 it contains much non-biodegradable or toxic matter and may need chemical or advanced treatment.
Mind map
Water and Wastewater Treatment and Management
- Pollutants
- Organic, inorganic
- Suspended, radioactive
- Heat (thermal)
- Monitoring
- Hardness: EDTA, EBT, pH 10
- pH: glass electrode
- DO: Winkler
- Chloride: Mohr's, AgNO3, K2CrO4
- Sources
- Point: pipes, outfalls
- Non-point: farm and urban runoff
- Lake problems
- Acidification
- Eutrophication: N, P, algae, low DO
- Thermal stratification: epi, thermo, hypo
- Treatment
- Primary: screen, grit, settle
- Secondary: activated sludge
- Tertiary: N, P, filtration, RO, disinfection
- BOD and COD
- BOD5 at 20 °C
- COD: dichromate reflux, FAS
- BOD/COD ratio
Activated sludge process step by step
- Raw sewage passes through screens and grit chambers to remove large solids and sand.
- In the primary clarifier, suspended solids settle as primary sludge; settled sewage overflows.
- Settled sewage enters the aeration tank and mixes with return activated sludge, a dense population of bacteria and protozoa in flocs.
- Air is blown in to supply oxygen and keep the flocs suspended; microbes oxidise organic matter: organics + O2 → CO2 + H2O + new cells.
- After about 4 to 8 hours the mixed liquor flows to the secondary clarifier, where the flocs settle quickly.
- Part of the settled sludge is returned to the aeration tank to maintain the microbial population; the excess (waste activated sludge) goes to thickening and anaerobic digestion.
- The clear supernatant (BOD reduced by about 90 percent) is disinfected or sent to tertiary treatment before discharge or reuse.
Important definitions
| Term | Meaning |
|---|---|
| Hardness | Soap-consuming capacity of water, due to Ca and Mg salts; expressed as mg/L CaCO3 equivalent. |
| Temporary hardness | Hardness due to bicarbonates of Ca and Mg, removable by boiling. |
| Permanent hardness | Hardness due to chlorides and sulphates of Ca and Mg, not removed by boiling. |
| Dissolved oxygen | Mass of oxygen dissolved per litre of water. |
| BOD | Oxygen used by microbes to oxidise biodegradable organic matter in 1 L of water in 5 days at 20 °C. |
| COD | Oxygen equivalent of the matter oxidised by hot acidic dichromate in 1 L of water. |
| Point source | Pollution entering from a single identifiable outlet. |
| Non-point source | Diffuse pollution from large areas such as farmland and city streets. |
| Eutrophication | Nutrient enrichment of water causing algal blooms, oxygen depletion and ageing of lakes. |
| Thermal stratification | Layering of a lake into warm epilimnion, thermocline and cold hypolimnion. |
| Activated sludge | Biologically active flocs of microorganisms used to oxidise organic matter in aerated sewage. |
| Thermal pollution | Harmful rise in water temperature due to discharge of heated effluents. |
Formulas
| Formula | Meaning |
|---|---|
| \( \text{CaCO}_3\ \text{eq} = \dfrac{\text{mass of salt}\times100}{\text{molar mass of salt}} \) | Hardness due to a Ca or Mg salt (mg/L). |
| \( \text{Hardness} = \dfrac{V_{EDTA}\times(\text{mg CaCO}_3\text{ per mL EDTA})\times1000}{V_{sample}} \) | EDTA method result in mg/L. |
| \( pH = -\log_{10}[H^+],\ pH + pOH = 14 \) | Acidity at 25 °C. |
| \( DO = \dfrac{N_{thio}\times V_{thio}\times8\times1000}{V_{sample}} \) | Winkler method (mg/L). |
| \( Cl^- = \dfrac{N_{AgNO_3}\times V\times35.45\times1000}{V_{sample}} \) | Mohr's method (mg/L). |
| \( BOD = \dfrac{D_1 - D_2}{P},\ P = \dfrac{V_{sample}}{V_{bottle}} \) | BOD by dilution (mg/L). |
| \( COD = \dfrac{(V_b - V_s)\times N_{FAS}\times8\times1000}{V_{sample}} \) | COD by dichromate reflux (mg/L). |
| \( \%\ \text{removal} = \dfrac{\text{in} - \text{out}}{\text{in}}\times100 \) | Treatment efficiency. |
Key points to remember
- Hardness is expressed as CaCO3 equivalent because CaCO3 has molar mass 100 and is insoluble.
- EDTA titration at pH 10 with EBT: wine red to blue.
- Winkler: MnSO4 + alkaline KI-azide, acidify, titrate iodine with thiosulphate; equivalent weight of O2 = 8.
- Mohr's method: AgNO3 with K2CrO4 indicator at pH 7 to 8; end point brick red.
- Saturation DO is about 9 mg/L at 20 °C and falls as temperature rises.
- Eutrophication is driven mainly by phosphates and nitrates.
- Stratification: epilimnion, thermocline (metalimnion), hypolimnion; overturn in autumn.
- Primary treatment is physical; secondary is biological; tertiary removes nutrients, salts and pathogens.
- COD ≥ BOD; BOD/COD above about 0.5 means readily biodegradable.
- BOD takes 5 days; COD about 3 hours.
Solved examples
Example 1. 50 mL of standard hard water (1 mg CaCO3 per mL) required 25 mL of EDTA. 50 mL of a water sample required 15 mL of the same EDTA. After boiling, filtering and making up, 50 mL of the sample required 10 mL. Find total, permanent and temporary hardness.
50 mL SHW contains 50 mg CaCO3, so 25 mL EDTA ≡ 50 mg, and 1 mL EDTA ≡ 2 mg CaCO3. Total hardness \(= 15\times2\times1000/50 = 600\) mg/L. Permanent hardness \(= 10\times2\times1000/50 = 400\) mg/L. Temporary hardness \(= 600 - 400 = 200\) mg/L.
Example 2. A water sample contains Ca(HCO3)2 = 16.2 mg/L, Mg(HCO3)2 = 14.6 mg/L, CaSO4 = 13.6 mg/L, MgCl2 = 9.5 mg/L and NaCl = 5.85 mg/L. Find temporary and permanent hardness.
CaCO3 equivalents: Ca(HCO3)2 \(16.2\times100/162 = 10\); Mg(HCO3)2 \(14.6\times100/146 = 10\); CaSO4 \(13.6\times100/136 = 10\); MgCl2 \(9.5\times100/95 = 10\) mg/L. NaCl causes no hardness. Temporary = 10 + 10 = 20 mg/L; permanent = 10 + 10 = 20 mg/L; total = 40 mg/L.
Example 3. In a Winkler titration, 200 mL of a water sample needed 6.4 mL of 0.025 N sodium thiosulphate. Find the DO.
\(DO = 0.025\times6.4\times8\times1000/200 = 6.4\) mg/L.
Example 4. 50 mL of a water sample required 8.5 mL of 0.02 N AgNO3 in Mohr's titration (blank negligible). Find chloride content.
\(Cl^- = 0.02\times8.5\times35.45\times1000/50 = 120.5\) mg/L (as NaCl: \(0.02\times8.5\times58.44\times1000/50 = 198.7\) mg/L).
Example 5. 5 mL of wastewater is diluted to 300 mL in a BOD bottle. Initial DO is 8.6 mg/L and DO after 5 days at 20 °C is 4.1 mg/L. Find the BOD5.
P = 5/300. \(BOD = (8.6 - 4.1)/(5/300) = 4.5\times60 = 270\) mg/L.
Example 6. 25 mL of wastewater was refluxed with dichromate. The blank required 24.0 mL and the sample 14.5 mL of 0.1 N FAS. Find the COD and the BOD/COD ratio if BOD is 270 mg/L.
\(COD = (24.0 - 14.5)\times0.1\times8\times1000/25 = 9.5\times0.1\times320 = 304\) mg/L. BOD/COD = 270/304 = 0.89, so the waste is readily biodegradable and suits biological (activated sludge) treatment.
Example 7. 20 mL of an effluent in a COD test consumed 16.3 mL of 0.05 N FAS against a blank of 22.5 mL. Find the COD.
\(COD = (22.5 - 16.3)\times0.05\times8000/20 = 6.2\times20 = 124\) mg/L.
Example 8. A sewage treatment plant receives BOD 250 mg/L and discharges 20 mg/L. Find the percent removal. What is the pH of water with [H⁺] = \(10^{-8.4}\) mol/L?
Removal \(= (250 - 20)/250\times100 = 92\%\). pH = 8.4 (slightly alkaline, within 6.5 to 8.5).
Important questions and answers
Q1. Classify water pollutants with examples. (5 marks)
Organic: biodegradable sewage, food waste, oils, detergents, pesticides, phenols; they deplete DO. Inorganic: acids, alkalis, salts, nitrates, phosphates, fluoride, heavy metals (Hg, Pb, Cd, Cr, As); toxic or cause eutrophication. Suspended: silt, clay, organic particles; cause turbidity and siltation. Radioactive: U, Ra, Sr-90, I-131, Cs-137 from nuclear and medical sources; cause cancer and mutations. Heat: hot cooling water; lowers DO and harms aquatic life. (Pathogens are a biological category.)
Q2. Explain the determination of dissolved oxygen by Winkler's method with reactions. (5 marks)
Fix DO in the BOD bottle with MnSO4 and alkaline KI-azide: \(Mn^{2+} + 2OH^- \rightarrow Mn(OH)_2\), \(2Mn(OH)_2 + O_2 \rightarrow 2MnO(OH)_2\) (brown). Acidify with conc. H2SO4: \(MnO(OH)_2 + 4H^+ + 2I^- \rightarrow Mn^{2+} + I_2 + 3H_2O\). Titrate the liberated iodine with standard Na2S2O3 using starch near the end point (blue to colourless): \(I_2 + 2S_2O_3^{2-} \rightarrow 2I^- + S_4O_6^{2-}\). Calculation: DO = N × V × 8 × 1000/V(sample) mg/L. Sodium azide destroys nitrite which would otherwise liberate iodine and give high results.
Q3. Explain the EDTA method for hardness. (5 marks)
Principle: EDTA forms stable 1:1 complexes with Ca²⁺ and Mg²⁺ at pH 10. Procedure: standardise EDTA with standard hard water; titrate the sample buffered at pH 10 (NH4Cl-NH4OH) with EBT indicator: metal-EBT complex is wine red; EDTA takes the metal ions from EBT and at the end point free EBT gives blue. Repeat with boiled sample for permanent hardness. Calculate in mg/L CaCO3 equivalent: total, permanent, temporary = total − permanent.
Q4. What is eutrophication? Explain its causes, effects and control. (5 marks)
Nutrient enrichment of water bodies. Causes: phosphates and nitrates from sewage, detergents, fertiliser runoff, animal waste, industrial effluents. Effects: algal blooms and weed growth, turbidity, loss of light, decay of dead algae consumes DO leading to fish kills, anoxic bottom with H2S and methane, toxins from cyanobacteria, loss of biodiversity, bad taste and odour in drinking water, faster filling of the lake. Control: nutrient removal in sewage treatment, phosphate-free detergents, controlled fertiliser use, buffer strips, diversion of effluents, weed harvesting, aeration, dredging.
Q5. Explain thermal stratification of lake water. (5 marks)
In summer, surface water warms and becomes lighter; the lake forms an upper epilimnion (warm, mixed, oxygenated), a middle thermocline (rapid temperature change) and a lower hypolimnion (cold, dense, little light). The thermocline blocks mixing, so DO in the hypolimnion is used up by decomposition, which may make it anoxic, releasing Fe, Mn, phosphate and H2S from sediments and harming fish. In autumn the surface cools to the same density as the deep water and the lake overturns, mixing nutrients and oxygen. Winter stratification and spring overturn occur in cold regions because water is densest at 4 °C. Relevance: reservoir water quality depends on the depth of withdrawal; stratification makes eutrophication worse.
Q6. With a flow diagram explain the activated sludge process. (6 marks)
Flow: screens and grit chamber → primary clarifier → aeration tank (with return sludge and air) → secondary clarifier → disinfection → effluent; sludge line: waste sludge → thickener → anaerobic digester → drying. Working as in the flow above: aerobic microbes in suspended flocs oxidise organics; secondary clarifier separates flocs; recycling of sludge keeps MLSS high. Features: 85 to 95 percent BOD removal, compact, high quality effluent. Problems: power for aeration, sludge bulking, skilled operation needed.
Q7. Define BOD and COD. Explain their relevance in wastewater treatment. Why is COD greater than BOD? (6 marks)
Definitions as above. Relevance: BOD indicates the organic load that biological treatment must remove; used to size aeration tanks, decide oxygen supply, judge treatment efficiency and check effluent standards. COD gives a quick estimate (3 hours) of total oxidisable matter, used for daily plant control and for industrial wastes containing non-biodegradable or toxic organics; COD also helps choose dilutions for the BOD test. The BOD/COD ratio tells biodegradability and so the type of treatment. COD exceeds BOD because dichromate oxidises almost all organic matter, including non-biodegradable compounds (lignin, cellulose, many synthetics) and some inorganic reductants (Fe²⁺, sulphide, nitrite), while microbes oxidise only the biodegradable part, and only partly in 5 days.
Q8. Distinguish between point and non-point sources of water pollution. (3 marks)
Point sources discharge from a definite location (sewage outfall, factory pipe, power plant outlet); easy to identify, measure and treat; regulated by consents. Non-point sources are diffuse (agricultural and urban runoff, mining areas, atmospheric deposition); hard to locate and treat; controlled by land use practices and best management practices.
Exam tips
- Write the calculation formula with units before substituting in hardness, DO, chloride, BOD and COD numericals.
- In the EDTA problem, first find mg CaCO3 per mL of EDTA from the standard hard water.
- In BOD problems, P is a fraction; dividing by P is the same as multiplying by the dilution factor.
- For COD, subtract sample titre from blank titre (more dichromate used means less FAS needed).
- Draw a neat ASP flow diagram with recycle and waste sludge lines.
- For stratification draw a temperature-depth graph marking the three layers.
- Give reactions for Winkler and Mohr methods; they carry marks.
FAQs
Why is BOD measured at 20 °C for 5 days?
The standard conditions make results comparable. In 5 days at 20 °C about two thirds of the carbonaceous demand of sewage is exerted, which is enough to compare samples quickly.
Why is mercuric sulphate added in the COD test?
Chloride is oxidised by dichromate and would give a falsely high COD. Mercuric sulphate binds chloride as a stable complex, removing this interference.
Why does hot water from a power plant harm fish?
Warm water holds less oxygen, while fish need more oxygen at higher temperatures. It also speeds up decay that uses oxygen and can exceed the temperature tolerance of species.
What is the difference between primary and secondary sludge?
Primary sludge is the raw solids settled in the primary clarifier. Secondary sludge is the excess microbial biomass from biological treatment. Both are usually digested anaerobically to produce biogas.
These notes follow the University of Mumbai first-year engineering syllabus (NEP 2020, Environmental Chemistry and Non-conventional Energy Sources) and were prepared with AI help and checked.
More in Environmental Chemistry and Non-conventional energy sources
See all →- Air Pollution Notes FE Sem 2 Environmental Chemistry | MU MU FE Sem 2 Environmental Chemistry Module 1: acid rain, ozone hole, photochemical smog, measuring and controlling SOx, NOx, CO, HC, catalyt...
- Waste Management Notes FE Sem 2 Environmental Chemistry | MU MU FE Sem 2 Environmental Chemistry Module 3: integrated solid waste management, waste hierarchy, Indian rules, hazardous waste and its trea...
- Renewable Energy Notes FE Sem 2 Environmental Chemistry | MU MU FE Sem 2 Environmental Chemistry Module 4: need for non-conventional energy; hydro, solar, wind, biomass, tidal and geothermal availabili...
- Biomass and Fuel Cell Notes FE Sem 2 Environmental Chemistry | MU MU FE Sem 2 Environmental Chemistry Module 5: biomass sources, pyrolysis, gasification, anaerobic digestion, biofuels and the hydrogen-oxyge...
- Sustainable Practices Notes FE Sem 2 Environmental Chemistry | MU MU FE Sem 2 Environmental Chemistry Module 6: energy resources, world consumption patterns, resource management, environmental ethics, energ...